This means that unknown and therefore unwanted heat loss flows through the surrounding atmosphere can be avoided, which can improve the measurement accuracy and therefore the significance of a measurement. In order to achieve a sufficiently high vacuum quality, it is important to use materials that are suitable for vacuum. For example, Pt100 temperature sensors with PTFE-insulated leads are used for temperature measurement. The signal and power cables have a vacuum-compatible Kapton® sheath. To increase the temperature measurement accuracy, a heat-conducting paste specially designed for vacuum applications is used. In addition to signal and power feed-throughs, the vacuum chamber has special feed-throughs for operating fluid-based heat exchangers.
TECHNICAL DATA:
- Stainless steel vacuum chamber (0.5 m x 0.5 m x 0.5 m) with transparent acrylic glass door
- 13 chamber outlets for signal, power and fluid feed-through
- Pumping unit consisting of rotary vane pump with 2.5 l/s pumping speed at 3,000 rpm and turbomolecular pump with >220 l/s pumping speed at 60,000 rpm
- Vacuum quality: high vacuum (< 10-5 hPa)
- Pressure measurement using Pirani/cold cathode transmitter
LOCATION:
Pinkafeld
CONTACT PERSON:
DI Sebastian Schuh BSc